.. _extended_swacc:
Read/Write-specific swacc
=========================
SystemRDL defines the ``swacc`` property, but it does not distinguish between
read and write operations - it is asserted on *all* software accesses.
Similarly, the spec defines ``swmod`` which gets asserted on software writes,
but can also get asserted if the field has on-read side-effects.
What if you just wanted a plain and simple strobe that is asserted when software
reads or writes a field? The ``rd_swacc`` and ``wr_swacc`` UDPs provide this
functionality.
Properties
----------
These UDP definitions, along with others supported by PeakRDL-busdecoder can be
enabled by compiling the following file along with your design:
:download:`busdecoder_udps.rdl <../../hdl-src/busdecoder_udps.rdl>`.
.. describe:: rd_swacc
If true, infers an output signal ``hwif_out..rd_swacc`` that is asserted
when accessed by a software read operation. The output signal is asserted
on the same clock cycle that the field is being sampled during the software
read operation.
.. wavedrom::
{"signal": [
{"name": "clk", "wave": "p...."},
{"name": "hwif_in..next", "wave": "x.=x.", "data": ["D"]},
{"name": "hwif_out..rd_swacc", "wave": "0.10."}
]}
.. describe:: wr_swacc
If true, infers an output signal ``hwif_out..wr_swacc`` that is asserted
as the field is being modified by a software write operation.
.. wavedrom::
{"signal": [
{"name": "clk", "wave": "p....."},
{"name": "hwif_out..value", "wave": "=..=..", "data": ["old", "new"]},
{"name": "hwif_out..wr_swacc", "wave": "0.10.."}
]}